Refrigerant Gas Monitors | Photoacoustic IR Detection

Photoacoustic infrared refrigerant gas monitors deliver highly sensitive, accurate leak detection for commercial HVAC, chiller rooms and industrial applications.

Photoacoustic Infrared Refrigerant Monitoring for Maximum Accuracy & Sensitivity

High-sensitivity photoacoustic infrared refrigerant gas monitor providing 1ppm leak detection and highly selective performance.
Highly selective single gas monitor with sensor and controller all-in-one, with 1,2,4, or 8 channels. Three alarms are adjustable between 10 ppm and full scale. Optionally, monitor up to 3 different gases simultaneously from up to 24 points by adding Remote IR modules and Channel Scanners.

Cost-effective multi-gas refrigerant monitoring using wideband photoacoustic infrared technology with 20ppm sensitivity.
Haloguard III features wideband photoacoustic infrared (PIR) technology for monitoring up to 8 gases with sensor and controller all-in-one. Three alarms are adjustable between 50 ppm and full scale.

Remote IR Modules expand ThermGAS photoacoustic infrared refrigerant monitoring systems to support up to 24 sample points. Each remote infrared sensor module (2 max per instrument) expands the Haloguard IR or Haloguard III sensing capability by up to eight channels. Connects to the controller via a 4-20mA output, using a two conductor twisted pair cable, allowing the module to be placed near the area to be monitored, thus minimizing sample tubing distance.

Refrigerant Monitors for Chiller Room and Commercial HVAC

ThermGAS refrigerant monitors provide continuous leak detection for chiller rooms, mechanical rooms, commercial HVAC systems, cold storage facilities and other applications where early identification of refrigerant leaks is critical.

Our photoacoustic infrared refrigerant monitoring systems are designed for high sensitivity, long-term stability and dependable operation. ThermGAS can monitor a single refrigerant or multiple gases.  Systems can be configured for single point or multi point applications.

Early refrigerant leak detection helps protect personnel and reduce refrigerant loss. Timely detection can also identify equipment problems and support safe operation of HVAC and refrigeration systems.

What Is a Refrigerant Monitor?

A refrigerant monitor continuously samples the surrounding air to detect the presence and concentration of refrigerant gas. Unlike a simple refrigerant leak detector used by a service technician to locate a leak, a fixed refrigerant gas monitor remains installed in the facility and continuously watches for rising refrigerant concentrations.

When a programmed alarm level is reached, the monitoring system can provide local alarms and interface with building controls, ventilation systems or other safety equipment.

Refrigerant monitors are commonly installed in:

  • Chiller rooms
  • Mechanical rooms
  • Commercial HVAC facilities
  • Data centers
  • Cold storage and refrigeration facilities
  • Manufacturing facilities
  • Laboratories and clean rooms

Refrigerant Leak Detection for Chiller and Mechanical Rooms

A refrigerant leak can develop slowly or occur suddenly from piping, valves, compressors, chillers or other refrigeration equipment.

High-sensitivity refrigerant monitoring provides an early indication of leakage before a developing problem becomes more serious.

ThermGAS photoacoustic infrared systems are particularly well suited to large mechanical and chiller rooms where centralized monitoring of multiple locations may be required. Remote sampling allows multiple potential leak locations to be monitored from a central instrument.

ThermGAS systems can be expanded to monitor up to 24 sample points, depending on system configuration.

Photoacoustic Infrared Refrigerant Monitoring

ThermGAS uses Photoacoustic Infrared technology to provide highly sensitive refrigerant gas detection.

Photoacoustic infrared measurement works by exposing a gas sample to infrared energy at wavelengths absorbed by the target refrigerant. The absorbed energy creates a measurable pressure signal that corresponds to the concentration of refrigerant in the sample.

Because the measurement is made directly from the gas sample, Photoacoustic Infrared technology provides excellent sensitivity and long-term measurement stability.

The ThermGAS Haloguard IR provides refrigerant detection sensitivity as low as 1 ppm for applications requiring highly sensitive and selective monitoring. For facilities monitoring several refrigerants, the Haloguard III provides wideband photoacoustic infrared monitoring for multiple gases.

Photoacoustic Infrared vs. NDIR Refrigerant Monitors

Different infrared technologies can be used for refrigerant gas detection. Traditional non-dispersive infrared, or NDIR, instruments determine refrigerant concentration by measuring infrared absorption. Photoacoustic infrared technology measures the pressure changes created when the target gas absorbs infrared energy. The absorbed infrared energy produces minute pressure oscillations, or acoustic waves, that are detected and used to determine gas concentration.

ThermGAS photoacoustic infrared technology is designed to provide stable measurements without relying on the same type of reference-gas comparison used by some infrared monitoring technologies.

For applications where low-level leak detection, selectivity and long-term stability are important, photoacoustic infrared monitoring can provide significant advantages.

Learn more about ThermGAS Photoacoustic Infrared Refrigerant Monitoring Technology.

ASHRAE 15 Refrigerant Monitoring

Refrigerant detection is an important part of mechanical-room safety.

ASHRAE Standard 15 includes refrigerant detection, alarm and ventilation requirements for applicable refrigerating machinery rooms. Detector selection, alarm settings and system design depend on the refrigerant, equipment, facility and applicable code requirements.

ThermGAS refrigerant monitoring systems can be integrated with alarms, ventilation controls and building management systems as part of a properly designed mechanical-room safety system.

System requirements should always be evaluated using the applicable edition of ASHRAE Standard 15, local mechanical codes and requirements of the authority having jurisdiction.

A2L Refrigerant Detection

The transition toward lower-global-warming-potential refrigerants has increased the use of A2L refrigerants in commercial HVAC and refrigeration equipment. Because A2L refrigerants are classified as mildly flammable, refrigerant detection and ventilation can play an important role in system and facility safety.

ThermGAS provides refrigerant monitoring solutions for commercial HVAC applications involving traditional refrigerants as well as newer low-GWP and A2L refrigerants.

For projects involving A2L refrigerants, ThermGAS can help determine the appropriate monitoring technology, number of monitoring points and system configuration for the application.