Refrigerant Leak Detection for HVAC, Chiller Plants & Critical Cooling

ThermGAS provides fixed refrigerant monitoring for commercial HVAC, central chiller plants, mechanical rooms, data centers, refrigeration and process cooling applications. For applications where early leak detection matters, Haloguard IR⁠ uses photoacoustic infrared technology to detect refrigerant concentrations down to 1 ppm.

Refrigerant Monitoring Applications

Refrigerant monitoring requirements vary with the equipment, refrigerant charge and reason for monitoring. A large centrifugal chiller, an A2L commercial HVAC system and a cold-storage refrigeration system have very different operating conditions and refrigerant profiles. ThermGAS refrigerant monitoring systems⁠ can be configured around the actual refrigerant and application, whether the objective is early leak detection, refrigerant conservation, equipment protection or facility safety. ThermGAS refrigerant monitoring systems support central chiller plants, mechanical rooms, commercial HVAC systems, data centers, hospitals, universities, manufacturing facilities, food processing, cold storage and process cooling applications. ThermGAS works with consulting engineers, mechanical contractors, HVAC and refrigeration professionals, facility managers, building owners and equipment manufacturers to configure monitoring systems around the refrigerant, equipment and application. For applications requiring low-level leak detection, ThermGAS photoacoustic infrared refrigerant monitoring technology⁠ provides sensitive, selective measurement down to 1 ppm.

Double blue ticks icon

Chiller Plants & Mechanical Rooms

 
Large water-cooled chillers can contain significant refrigerant charges and numerous potential leak points, including compressors, valves, seals, fittings and piping connections.Depending on the equipment and generation, chiller plants may use refrigerants including R-134a, R-513A, R-514A, R-1233zd(E), R-1234ze(E) and R-515B.A developing leak may remain unnoticed long before refrigerant loss begins to affect cooling capacity. Continuous monitoring provides an earlier indication that refrigerant is escaping. Haloguard IR⁠ provides 1 ppm sensitivity, giving maintenance teams an opportunity to investigate low-level leaks before they become larger refrigerant losses. Proper sampling location is also important.
Double blue ticks icon

Commercial HVAC, Data Centers & A2L Refrigerants

 
 
Commercial HVAC is transitioning from higher-GWP refrigerants such as R-410A toward lower-GWP A2L refrigerants including R-32 and R-454B.
These refrigerants introduce additional considerations for leak detection, equipment controls, ventilation and system design. Early leak monitoring can identify refrigerant before a developing leak becomes a larger problem, while detectors required for equipment or code-mandated safety functions may serve a different purpose.
 
 
For information on the U.S. transition toward lower-GWP refrigerants, visit the EPA Technology Transitions Program⁠.
Double blue ticks icon

Cold Storage, Refrigeration & Process Cooling

 
Cold storage, food processing, commercial refrigeration and manufacturing facilities rely on refrigeration and process cooling to protect products, equipment and production.Existing refrigeration systems may still operate with refrigerants such as R-404A and R-507A, while lower-GWP alternatives include refrigerants such as R-448A, R-449A and R-455A, depending on the equipment and application.Process chillers may instead use refrigerants found in commercial chiller systems, including R-134a, R-513A or R-1234ze(E).This is why refrigerant monitoring should be selected around the actual equipment and gas present rather than treating every industrial application the same. Continuous monitoring can provide earlier warning of refrigerant loss before it affects equipment efficiency, product temperature, process stability or production. View the full list of gases we can detect.
 
 
Double blue ticks icon

Data Centers & Critical Cooling

 
Data centers, hospitals, laboratories, universities and other critical facilities depend on reliable cooling to protect equipment and operations.
Large chilled-water systems serving these facilities may use refrigerants such as R-134a, R-513A, R-1233zd(E), R-1234ze(E) and R-515B, depending on the installed chiller equipment. A small refrigerant leak may not immediately reduce cooling capacity. High-sensitivity monitoring can identify a developing leak earlier, giving facility teams additional time to locate and repair the problem before cooling performance is affected.
In a critical cooling environment, finding the leak early helps protect uptime.
Learn more about Refrigerant Monitoring for Data Centers⁠.