TracePoint 1000 Refrigerant & Specialty Gas Monitor
Photoacoustic infrared gas detection with sensitivity down to 0.5 ppm.
Description
TracePoint 1000 Refrigerant & Specialty Gas Monitor
TracePoint 1000 is a dedicated single-point refrigerant and specialty gas monitor designed for continuous leak detection. It uses proven photoacoustic infrared technology to detect gas concentration down to 0.5 ppm sensitivity. The monitor provides a 0-1000 ppm measuring range and a 4-20mA output for external monitoring and control systems. Installation close to the monitored area also helps reduce sample tubing distance.
High-Sensitivity Refrigerant Monitor
The TracePoint 1000 is designed for applications where accurate refrigerant & specialty gas monitoring is critical. Photoacoustic infrared measurement technology provides precise gas detection with minimal drift and low cross-sensitivity compared with many conventional sensing technologies. The monitor is well suited for mechanical rooms, chiller plants, data centers, laboratories, manufacturing facilities and other locations where early refrigerant & specialty gas leak detection is important.
Designed for Continuous Leak Detection
TracePoint 1000 continuously samples the monitored area and provides fast identification of refrigerant leaks. With sensitivity down to 0.5 ppm, the system can detect low-level leaks that may not be identified by less sensitive monitoring technologies. The unit provides a 4–20 mA output for integration with building automation, safety and facility monitoring systems. Its NEMA 4/12 enclosure supports installation in demanding industrial environments.
Photoacoustic Infrared Technology
ThermGAS photoacoustic infrared technology is designed for reliable, long-term gas monitoring with minimal consumables. The technology provides excellent sensitivity while maintaining stable performance over extended periods of operation. The TracePoint 1000 refrigerant & specialty gas monitor is engineered for facilities that require dependable, continuous gas detection and early warning of leaks.
Specifications
| Technology | Photoacoustic infrared |
| Electrical Supply | 115-230v, 50-60 Hz, 65W |
| Output Signal | 4-20mA analog output |
| Sensitivity | 0.5 ppm |
| Resolution | 0.5 ppm |
| Measuring Range | 0 - 1000 ppm all refrigerants and specialty gases |
| Maximum Sample Point Tubing Length | 150 ft with standard performance, 500 ft optional where slower response is acceptable. |
| Operating Conditions | 30°F to 120°F non-condensing |
| Enclosure | Std: NEMA 4/12 |
| Weight | 8 lbs. |
| Sample Rate | 1.5 lpm |